home *** CD-ROM | disk | FTP | other *** search
- Contents
- 1) Setting up the USB function
- (for the EIZO FlexScan F67/T68/FX-D7/TX-D7/E67F/E67T monitor
- and the i-Station)
- 2) Setting up the "ScreenManager Pro for USB"
- 3) Update History
- 4) How to update
-
- =============================================================================
- 1) Setting up the USB function
- (for the EIZO FlexScan F67/T68/FX-D7/TX-D7/E67F/E67T monitor
- and the i-Station)
- =============================================================================
- NOTE: To utilize the USB hub function, the following system environment
- is required.
- * USB compliant PC or another USB hub connected to the USB compliant
- PC
- * OS (Windows 98)
- * EIZO USB cable (MD-C93)
-
- Monitor USB function setup
- (1) Copy the downloaded files into the floppy disk and insert the disk into
- the floppy disk drive.
- (2) When using the i-Station, connect the serial port of the i-Station
- to the maintenance port of the monitor with the EIZO maintenance port
- cable (MD-C94).
-
- NOTE
- When using a model which does not have a maintenance port or not using
- "ScreenManager Pro for USB", procedure (2) does not need to be done.
-
- (3) Connect the upstream port of the monitor (or the i-Station)
- to the downstream port of the USB compliant PC or another hub using
- the EIZO USB cable (MD-C93).
- (4) "EIZO USB Hub" appears on the screen. Insert the Windows 98 CD-ROM
- and click "OK" in the "Insert Disk" window. Follow the instruction
- of the window.
-
- NOTE
- If the step (2) is skipped, the USB function setup is completed here.
-
- (5) After the setup of the USB Hub, "Add New Hardware Wizard" window appears
- on the screen, and "Unknown Device" is detected.
- (6) Click the "Next" button.
- (7) Select the "Search for the best driver for your device (recommend)"
- button, and click the "Next" button.
- (8) Select the "Floppy disk drivers" and click the "Next" button.
- (9) "EIZO USB Monitor" appears on the screen. Follow the instruction of the
- window.
-
- Once the above operation is completed, the monitor (or the i-Station)
- functions as a USB hub and the USB compliant peripherals can be connected
- to the downstream ports of the monitor.
-
- Confirmation of USB setup
- Please make sure the proper installation is completed by following
- the confirmation below.
- (1) Click the "Start" button and open the "Control Panel" from the
- "Settings".
- (2) Select and double click the "System" from the "Control Panel" to open
- the "System Properties".
- (3) Confirm if the followings are in the "Device Manager" window:
- * "EIZO USB Hub" and "EIZO USB Monitor" appear under "Universal
- serial bus controller".
- The two points indicated that the settings were properly installed.
- If the step (2) is skipped, the "EIZO USB Monitor" is not appeared.
-
-
- =============================================================================
- 2) Setting up the "ScreenManager Pro for USB"
- =============================================================================
- NOTE
- Please install this program after the above setup (USB function setup) has
- been completed.
- "ScreenManager Pro for USB" cannot be used with the following environment.
- * EIZO LCD display monitors
- * i-Station with any model which does not have a maintenance port.
-
- ScreenManager Pro for USB is the utility for adjusting the display from
- the PC using the mouse or keyboard through the USB interface.
- This utility has the following features:
-
- (1) Some unique adjustment functions which are not supported with the
- ScreenManager are available.
- (2) Easier adjustment via a mouse and a GUI application.
- (3) An adjustment menu with grids can be displayed for the accurate
- screen adjustment. (Two method to adjust are available.)
- (4) Adjustment data (screen data, color data) can be stored in the PC
- for latter use.
-
- Installation procedure
-
- (1) Download the "ScreenManager Pro for USB for Windows 98" and copy the
- extracted files into the floppy disk and insert the disk into the floppy
- disk drive.
- (2) Execute the "setup.exe" program in the floppy disk.
- (3) Follow the procedure displayed on the screen.
- (4) When the setup is completed, click the "Advanced" button at
- the "Settings" tab of "Display Properties" to see "EIZO" tab is added
- there. The monitor control function is available.
-
- NOTE
- ò The functionality differs with each monitor. Some functions may not be
- available to use with some monitors.
-
-
- Note when updating Windows 95 to Windows 98
-
- When updating the system from Windows 95 to Windows 98, setup the Screen
- Manager Pro for USB software as follows:
-
- (1) Start Windows 98 with connecting display with PC by the USB cable.
- (2) Select "Add/Remove Programs" from the Control Panel and select
- "Install/Uninstall" tab.
- (3) Select "ScreenManager Pro for USB" as an uninstall program and click
- "Add/Remove.." button.
- (4) After removing the program, follow the messages and restart Windows 98.
- (5) When Windows 98 starts, select "System" from the Control Panel and
- select "Device Manager" tab.
- (6) Select "EIZO USB Monitor" under the "Universal serial bus controller"
- in the device list and click "Properties".
- (7) Select "Driver" tab and click "Update Driver.." button.
- (8) Click "Next" button in the "Update Device Driver Wizard" menu.
- (9) Select "Search for a better driver than the one your device is using now."
- and click "Next" button.
- (10) Insert the floppy disk containing the ScreenManager Pro for USB for
- Windows 98 into the floppy disk drive.
- (11) Select "Floppy disk drives" and click "Next" button.
- (12) Finish Updating the driver following the messages.
- (13) Remove the floppy disk and restart Windows 98.
- (14) Insert the floppy disk containing the "ScreenManager Pro for USB for
- Windows 98" into the floppy disk drive.
- (15) Double click "setup.exe" in the floppy disk and install the ScreenManager
- Pro for USB following the messages.
-
- =============================================================================
- 3) Update History
- =============================================================================
- V1.01 : The following problem with V1.00 driver has been fixed;
- After finish setting up the USB function on WIndows 98, click "Start"
- button on the tool-bar and select "Shut Down". Then select "Stand by"
- and click "OK" button. The computer will go into the "Stand by" mode.
- (With some computers which do not support "Stand by" mode, "Stand by"
- can not be selected.)
- Then move mouse to activate the system, however the system can not be
- recovered from the "Stand by" mode.
-
- =============================================================================
- 4) How to update
- =============================================================================
- (1) Start Windows 98 with connecting display with PC by the USB cable.
- (2) Click "Start" button and click "Control Panel" from the "Settings".
- (3) Double click "System" from the "Control Panel".
- (4) Select "Device Manager" in the "System Properties".
- (5) Double click "Universal serial bus controller" from the displayed device
- list.
- (6) Double click "EIZO USB Monitor" displayed under the "Universal serial bus
- controller".
- (7) Select "Driver" in the "EIZO USB Monitor Properties".
- (8) Click "Update Driver" button.
- (9) "Update Device Driver Wizard" menu is displayed, then click "Next" button.
- (10) Mark "Search for a better driver than the one your device is using now"
- and click "Next" button.
- (11) Select "Floppy disk drives" as a target drive and insert the driver
- diskette into the floppy disk drive then click "Next" button.
- (12) "Windows driver file search for the driver: EIZO USB Monitor" is displayed
- then click "Next" button.
- (13) "EIZO USB Monitor Windows has finished installing an updated driver for
- your hardware device." is displayed then click "Finish" button.
- (14) Remove the driver diskette from the floppy disk drive and restart the
- computer following the displayed messages.
-
- Update confirmation
- (1) Click "Start" button and click "Control Panel" from the "Settings".
- (2) Double click "System" from the "Control Panel".
- (4) Select "Device Manager" in the "System Properties".
- (5) Double click "Universal serial bus controller" from the displayed device
- list.
- (6) Double click "EIZO USB Monitor" displayed under the "Universal serial bus
- controller".
- (7) Select "Driver" in the "EIZO USB Monitor Properties".
- (8) Click "Driver File Details.." button.
- (9) Check that the driver version is displayed as "File version: 1.01.0000".